欢迎来到报告吧! | 帮助中心 分享价值,成长自我!

报告吧

换一换
首页 报告吧 > 资源分类 > PDF文档下载
 

街道照明:过载保护带来的挑战(英文版).pdf

  • 资源ID:93593       资源大小:1.05MB        全文页数:6页
  • 资源格式: PDF        下载积分:15金币 【人民币15元】
快捷下载 游客一键下载
会员登录下载
三方登录下载: 微信开放平台登录 QQ登录  
下载资源需要15金币 【人民币15元】
邮箱/手机:
温馨提示:
用户名和密码都是您填写的邮箱或者手机号,方便查询和重复下载(系统自动生成)
支付方式: 支付宝    微信支付   
验证码:   换一换

加入VIP,下载共享资源
 
友情提示
2、PDF文件下载后,可能会被浏览器默认打开,此种情况可以点击浏览器菜单,保存网页到桌面,既可以正常下载了。
3、本站不支持迅雷下载,请使用电脑自带的IE浏览器,或者360浏览器、谷歌浏览器下载即可。
4、本站资源下载后的文档和图纸-无水印,预览文档经过压缩,下载后原文更清晰。
5、试题试卷类文档,如果标题没有明确说明有答案则都视为没有答案,请知晓。

街道照明:过载保护带来的挑战(英文版).pdf

Outdoor Lighting White paper Street Lighting The challenges of surge protectionThe need for protection Voltage surges have a huge destructive impact upon public lighting systems. They wear out LED drivers and distribution panels prematurely, and increase service interruptions to street lighting. Beyond material damage to the luminaires, voltage surges caused by lightning, for example, can trigger or break protective devices in the circuit boards of street lighting distribution panels. So as well as the cost of replacing hardware, the public is left without lighting a critical safety issue in the case of pedestrian and traffic tunnels, road signs and other public lighting. The vulnerability of electronic lighting systems to overvoltages is widely recognized in technical literature, and different European regulations and standards specify the need for lighting protection. This white paper explains the causes of lighting overvoltages and how they affect public lighting installations. It also covers the legal and regulatory framework governing protection, and proposes a solution to maximize protection performance and continuity of service. Public lighting installations are exposed to the environment. Located where continuity of service is essential, it is crucial that these installations are protected against lightning and overvoltages. Investing a small amount in protection can extend luminaire lifetime, improve public services and greatly reduce overall operating and infrastructure costs. The challenges of surge protection 2 I/2 I/2 I I I = current I The challenges of surge protection 3 Building-in protection What are transient or surge overvoltages? When analyzing the phenomenon of overvoltages, we consider surge overvoltages and power-frequency overvoltages separately. Although they both represent an increase in voltage above an acceptable limit, their root causes, magnitude, duration and method of protection are radically different. Surge overvoltages are spikes that can reach tens of kilovolts but last for only a few microseconds. Despite their short duration, their high energy content may cause serious problems to equipment connected to the electricity network from premature aging to destruction resulting in service disruptions and costly repairs. Voltage surges have several causes. For example, lightning discharges that directly strike the distribution line of a building, or its lightning rod, can induce electromagnetic fields that generate voltage spikes in nearby lighting installations. And very long outdoor distribution power lines are highly susceptible to the direct effects of lightning strikes, with large currents from the lightning being conducted in the power lines. Its also common for non-weather phenomena to cause voltage spikes in adjacent lines for instance, switching inside transformer cabinets, or the disconnection of motors and other inductive loads. Surge overvoltages are voltage spikes of several kilovolts that last for just a few microseconds Surge overvoltages have two modes of circulation: common and differential. Common-mode overvoltages appear between the live conductors and earth: for example, line-to-earth or neutral-to-earth. Differential-mode overvoltages circulate between live conductors: line-to-line or line-to-neutral. A well-protected luminaire should integrate protection for both modes. Fig.2 Definition of common and differential-mode currents Surge overvoltage protection is provided by installing a protective device (surge arrester) on the vulnerable line, and connecting it in parallel or in series. When connected in series, the protection device acts as a fuse. But when its connected in parallel, the luminaire continues to function even after the Surge Protection Device (SPD) is damaged. The SPD will get damaged after weathering a number of spikes above a certain voltage level. In the event of a surge overvoltage, the protective device will divert excess energy to earth, thus limiting the peak voltage to a tolerable level for the electrical equipment connected downstream. Fig.1 Transient “surge” overvoltage Protecting against the effects of surge overvoltages in public lighting An SPD acts as a voltage-controlled switch. When the network voltage is lower than the activation voltage, the component is passive. On the other hand, when the network voltage exceeds the activation voltage, the SPD diverts the surge energy and prevents it from destroying the equipment. When choosing an SPD, you need to consider the equipments exposure to the effects of lightning, along with the maximum impulse voltage that the equipment needs to withstand. Fig.3 Working principle of a surge protection device (SPD) In general, the most effective approach to protect large installations of lighting equipment against surge overvoltages is by cascading multiple protective stages. Each stage combines the necessary balance between discharge capacity and voltage protection level. This way, a first stage (typically a Type 1 or Type 2 SPD) provides robustness, thus diverting most of a spikes energy, while a second stage (typically a Type 2 or Type 3 SPD) provides fine protection. Thus the peak voltage reaching the equipment always stays below the critical level. Of the causes of surges mentioned in international protection standards, the ones most likely to affect a public lighting system are: direct lightning strikes on distribution lines (conducted through the power lines), and lightning strikes near to a building/structure (creating induced surges). European standards EN 60.364-5-534 and EN 62.305-1 require that protection against these types of electrical disturbance are to be provided by a Type 2 SPD. The protection solution is installed downstream of the main circuit breaker in the distribution panel circuit board, in parallel to the main system. So it diverts the energy of the surge to earth, limiting the voltage peak to a tolerable level for equipment connected downstream. To guarantee proper protection of a luminaire, the distance between it and its protector circuit must be as short as possible. If the distance between a protected distribution panel and several luminaires is more than 20 meters, using a second protection stage (of Type 2 or 3) is recommended, even if the protection level of the first stage seems to be sufficient (see Fig.4). Fig.4 Effect of cable distance on the voltage protection level The challenges of surge protection 4The challenges of surge protection 5 Practical approach Stage 1: Standard protection at luminaire level IEC61547 states that all luminaires should be protected from overvoltages up to 1 kV in differential mode and 2 kV in common mode. However, Philips has decided to exceed these requirements. All Philips luminaires have a minimum protection of 4 kV, in both common and differential modes. This level ensures acceptable protection for most European street- lighting installations, and therefore makes all Philips luminaires suitable up to Class 4 installations (as defined in EN61000-4-5). Stage 2: Additional protection of luminaires When designing installations, the area should be assessed for its vulnerability to lightning strikes. If the vulnerability is high, 10 kV protection is recommended. In these cases, Philips recommend the use of an SPD, in addition to the standard protection at luminaire level to ensure a higher level of protection (10 kV). This solution will be offered to Philips customers upon request. Stage 3: Distribution panel board protection In the most vulnerable environments, the V-check 4RC solution offered by our partner Cirprotec can be installed on a DIN rail of 4 modules. It protects not only surge overvoltages (max surge current of 40 kA) but also power-frequency overvoltages. Power-frequency overvoltages are often caused by insulator breakdown in circuitry. The V-Check 4RC automatically reconnects the power supply after the surge has finished. cirprotec Fig.5 Circuit protection solutions for luminaires and street-lighting distribution panels Inside the luminaire Inside the panel© 2014 Koninklijke Philips N.V. All rights reserved. Philips reserves the right to make changes in specifications and/or to discontinue any product at any time without notice or obligation and will not be liable for any consequences resulting from the use of this publication. philips lighting.philips

注意事项

本文(街道照明:过载保护带来的挑战(英文版).pdf)为本站会员(爱国者)主动上传,报告吧仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对上载内容本身不做任何修改或编辑。 若此文所含内容侵犯了您的版权或隐私,请立即通知报告吧(点击联系客服),我们立即给予删除!

温馨提示:如果因为网速或其他原因下载失败请重新下载,重复下载不扣分。




关于我们 - 网站声明 - 网站地图 - 资源地图 - 友情链接 - 网站客服 - 联系我们

copyright@ 2017-2022 报告吧 版权所有
经营许可证编号:宁ICP备17002310号 | 增值电信业务经营许可证编号:宁B2-20200018  | 宁公网安备64010602000642号


收起
展开